UniFi Gate Hub
Ubiquiti UA-Hub-Gate UniFi Gate Hub
SKU:UA-Hub-Gate
Regular price
$494.00
Regular price
$559.00
Sale price
$494.00
Unit price
per
Out of stock
Authorised Reseller | Australian Stock | Australian Warranty
An advanced Gate Hub enabling seamless gate access control via connected Access readers or Intercom.
- (2) Gate operator terminals (dry).
- (1) Lock terminal (12V) for side door.
- (1) AUX terminal for an external siren.
- (5) Additional inputs (sensors and emergency).
- License plate unlock (when paired with AI Camera).
- Connect and power using PoE++.
- Connect up to four UniFi Access readers or UniFi Protect cameras.
Optional LPR Cameras:
- UVC-AI-Turret,
- UVC-AI-LPR,
- UVC-AI-Dome,
- UVC-AI-DSLR,
- UVC-AI-Pro,
- UVC-AI-Theta,
- UVC-AI-Bullet.
Mechanical | |
---|---|
Dimensions | 175 x 126 x 26 mm (6.9 x 5 x 1") |
Weight | 460 g (1 lb) |
Enclosure material | Polycarbonate |
Mounting | Din-rail (Included) |
Hardware | |
Networking interface | (5) 10/100/1000 Base-T |
Power method |
PoE++ UL 294 Power-limited Class 2 PSU UL 60950-1/62368-1 LPS/PS2 PSU |
Max. power consumption |
Without PoE output: 22W With PoE output: 50W |
PoE input | 50V DC, 1A |
PoE output | PoE passthrough, (4) PoE, 50V DC, Max. 28W |
LEDs | White/blue (Learn more) |
Button | (1) Factory-reset |
Digital input | Gate exit request, gate position, side door exit request, side door position, emergency |
Dry output relay |
(2) Operator: rated 30V DC, up to 1A (1) Aux: rated 30V DC, up to 1A |
Output relay | Side door lock: 12V DC, up to 1A |
PoE cabling requirements |
Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable. |
Operating environment |
Indoor use only with device itself Outdoor use with waterproof junction box |
Ambient operating temperature | -30 to 60° C (-22 to 104° F) |
Ambient operating humidity | 5 to 90% noncondensing |
Software information | The software version of a product can be checked at https://unifi.ui.com |
UL 294 level |
Destructive attack: Level I Line security: Level I Endurance: Level I Standby power: Level I |
UL 294 statement |
Compliance with IEEE 802.3 specifications was not verified as part of UL 294. The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits. |
PoE cabling requirements |
Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site. The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm 2 ) for patch cords; 24 AWG (0.21 mm 2 ) for horizontal or riser cable. |
CAN/ULC-60839-11-1 Grade | Grade assignment: I |
Certifications | CE, FCC, IC, UL 294, CAN/ULC-60839-11-1 |
Document number, and issue date and/or revision level | UA-Hub-Gate, V01 |
Recommend max. cable length
18 AWG UACC-Cable-DoorLockRelay length |
20 AWG length |
22 AWG length |
24 AWG length |
|
---|---|---|---|---|
UA-Lock-Electric (400mA) |
100 m (328 ft) |
66 m (217 ft) |
42 m (138 ft) |
25 m (82 ft) |
UA-Lock-Magnetic-270kg (800mA) |
46 m (151 ft) |
30 m (98 ft) |
20 m (66 ft) |
12 m (29 ft) |
UA-Lock-Magnetic-540kg (500mA) |
80 m (262 ft) |
51 m (167 ft) |
32 m (105 ft) |
20 m (66 ft) |
Other locks (1A) |
36 m (118 ft) |
24 m (79 ft) |
15 m (49 ft) |
9 m (30 ft) |
Visit Ubiquiti for more information.